Product renderings. Generator shown for scale.
Generator elevation stand ·
RhinoRisers 24 Generator Stand
Lift a home standby generator 24" off the pad, clear of snow drifts, standing water and splash-back. All-welded steel angle frame that bolts straight to the pad and the generator.
Included with every stand
- (4) 1/4-20 Gr5 HDG bolts, fender washers & nylock nuts, generator to stand
- (4) nylock nuts & washers for the pad's 1/4" cast-in anchors
- Shop drawings + wind & snow load calcs for your permit
Shipping estimate (ships from )
Enter a ZIP to estimate freight to your area.
- Local pickup
- Free
- Freight to a business (dock or forklift)
- Freight to a home (liftgate)
Ships on one small pallet by LTL freight. Checkout covers the stand. Freight is billed separately: we quote the exact rate for your address and invoice it before shipping. Pickup is free.
High-wind site? Earth anchor kit sold separately, .
- Mounting hardware and permit documents included
- Freight to your site or free local pickup
- Made by an electrical contractor that installs generators
Above the pad
Keeps air intake, exhaust and controls above deep snow and standing water.
Steel angle
2" × 2" × 1/8" A36 angle, mitered and fully welded. About 50 lb.
Bolt-down points
Matching hole patterns top and bottom: generator to stand, stand to pad.
Finishes
Bare, painted, galvanized or powder coated. Choose when you order.
Earth anchor kit
Order it with a stand or on its own. Check the calc sheet that comes with the stand to see whether your design wind speed calls for anchoring the pad.
Specifications
Every stand is built to the same shop drawings.
| Overall size | 46" L × 22" W × 24" H |
|---|---|
| Material | ASTM A36 steel angle, 2" × 2" × 1/8" |
| Construction | Top and bottom frames with 45° mitered corners, 4 nested legs, all joints welded |
| Top seat | 2" inward ledge the generator base sits on; 42" × 18" open center |
| Generator mounting | 4 × Ø5/16" holes for 1/4" bolts, 38-3/8" × 20-1/4" center to center |
| Pad mounting | 4 × Ø5/16" holes, same pattern directly below, fits the pad's pre-cast 1/4" anchors |
| Finish | Bare steel, painted steel, galvanized or powder coated |
| Included hardware | (4) 1/4-20 Gr5 HDG bolts with fender washers & nylocks; (4) nylocks & washers for the pad anchors |
| Shipping size | One pallet, about 48" × 40" × 30", about 90 lb |
| Stand weight | ≈ 50 lb |
| Checked for | 610 lb generator plus ground snow loads up to 100 psf; wind tabulated 100–180 mph (ASCE 7-22) |
| Built for | Generac 28 kW air-cooled home standby (48" × 26-5/16" × 30-11/16"). Other units with the same base hole pattern also fit. |
Drawings
The full 4-sheet set (assembly, details, installation, calculations) comes with every order.
Install in four steps
About an hour with two people, once the pad is set.
- Set the padLevel the pad on compacted gravel, within 1/4".
- Bolt the stand downDrop the stand over the pad's four 1/4" anchors. Washer and nylock each one.
- Set the generatorLine up the base holes with the stand's top holes, 38-3/8" × 20-1/4".
- Bolt the generatorFour 1/4-20 bolts with fender washers top and bottom. Snug tight; don't crush the base.
Keep Generac and NFPA 37 clearances. Gas and conduit connections will be about 30" above the pad, so plan the flex lines for that.
Freight delivery
Ships on one small pallet by LTL freight. Estimated to a business with a dock or forklift, or to a home with liftgate delivery. Freight is billed separately after checkout; we quote the exact rate for your address before it ships.
Local pickup
Free pickup at our shop. We'll call when it's ready.
Questions
Why raise a generator?
In heavy-snow areas and low spots that collect water, a unit on a bare pad can get buried or sit in water. Raising it 24" keeps the air intake, exhaust and controls clear.
Does the stand need to be anchored?
Yes. A raised generator catches more wind, so the stand always bolts to the pad's four cast-in anchors and the generator always bolts to the stand. Depending on your site's design wind speed, the pad may also need anchoring to grade. The calc sheet that comes with the stand covers this, and the earth anchor kit (sold separately) handles it.
Will my inspector accept it?
Every order comes with the shop drawings and a wind and snow load calculation sheet (ASCE 7-22) to submit with your permit. If your jurisdiction requires stamped drawings, ask us before ordering.
Can you build a different height or size?
Yes. Taller stands, other footprints and other hole patterns can be built to order. Send us your generator model and pad size.
What finish options are there?
Four finishes: bare steel, painted steel, galvanized or powder coated. Pick one in the order box. Bare steel ships unfinished, so you can paint or coat it yourself. Left uncoated outdoors, it will rust. Ask about custom colors.
Get a quote